Square 'D' Pressure Switch, Factory PSI Setting 80-100, Differential PSI 20 (Smaller HP) Square 'D' Pressure Switch, Factory PSI Setting 95-125, Differential PSI 30 (Smaller HP) Price: $44.82. Looking for SQUARE D Air Compressor Pressure Switch; Range: 40 to 150 psi, Port Type: (1) Port, 1/4 in FNPS (5B419)? Grainger's got your back. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more.
- POST a QUESTION or COMMENT about diagnosing, repairing, or replacing a well pump pressure control switch
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Water pressure control switch repair & installation manuals.
These water pump switch IO manuals for Square D, Pumptrol and similar water pressure control switches provide manufacturer's advice on selection, installation, and troubleshooting of these pressure controllers.
This article series describes how to repair a water presure control switch that sticks on, off, or chatters or is otherwise not working properly, causing loss of water pressure or irregular in cycling on and off. We discuss how to diagnose problems with the water pump control and how to fix them by correcting an underlying problem, by replacing a bad pressure control switch, or by replacing switch parts such as bad contacts or diaphragm.
We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.
Water Pump Pressure Control Switch IO Manuals
Following a list of helpful pump control diagnosis & repair articles we provide down-loads in PDF form of popular installation & operation manuals for various pump pressure control switches.
- How to Adjust Water Pump Pressure: The detailed, step by step procedure for inspecting and adjusting the water pressure control switch is discussed in detail at WATER PUMP PRESSURE CONTROL ADJUSTMENT.
- Diagnosing Water Pump Short Cycling on and off: If your water pump is clicking on and off too often or quite rapidly see SHORT CYCLING.
- Diagnosing & Repairing Lost Air in the Water Tank: The problem of lost air in the water pressure tank along with how to correct that condition are discussed beginning
at SIGNS OF AIR LOSS. - Diagnosing & Repairing a Water Pressure Control or Water Pump Control Switch: We discuss diagnosing and repairing a water pressure control switch that sticks 'on' or 'off' or simply won't operate,
at WATER PUMP PRESSURE SWITCH REPAIRS - starting at the top of this page. - Replacing a Bad Water Pressure Control Switch is discussed step by step
at PUMP PRESSURE CONTROL REPLACE - How to match the water pressure tank initial pressure to the pressure control switch cut-in pressure:
at WATER TANK BLADDER PRESSURE ADJUSTMENT we discuss fine tuning the pump pressure control switch to work perfectly with the exact air pressure pre-charge in a bladder type well tank. - General water pressure problem diagnosis:
see WATER PRESSURE PROBLEM DIAGNOSIS TABLE in table format listing nearly every cause of water pressure loss or well pump problem identification, diagnosis, and repair. - Access Water Energy, PO Box 2061, Moorabbin, VIC 3189, Australia, Tel: 1300 797 758, email: sales@accesswater.com.au Moorabbin Office: Kingston Trade Centre, 100 Cochranes Rd, Moorabbin, VIC 3189
Australian supplier of: Greywater systems, Solar power to grid packages, Edwards solar systems, Vulcan compact solar systems, water & solar system pumps & controls, and a wide rage of above ground & under ground water storage tanks: concrete, steel, plastic, modular, and bladder storage tanks. - Centipro PRessure Switch, 30-50 psi, 2 HP, GOU-CT-AS4
- EVERBILT PRESSURE SWITCH INSTALLATION GUIDE [PDF] HOMEDEPOT.com Please contact 1-844-251-7446 for further assistance; retrieved 2018/06/22, original source: https://images.homedepot-static.com/ catalog/pdfImages/ a0/a07da9c1-916b-4ed6-8d58-7def1ec35d96.pdf
- FLUX ELECTRONIC FLOW CONTROL SWITCH [PDF] used by Pedrollo water pumps & others
- Furnas Pressure Control Switches, Class 69ES-Pro Control™ (Pumps up to 5 hp), Hubbell Industrial Controls, Inc., 4301 Cheyenne Dr., Archdale NC 27262, USA, Tel: 336-434-2800, Website: www.hubbell-icd.com, Email: Sales@hubbell-icd.com
- Furnas Model AS41FX (30/50 pressure control), Furnas Motor Controls, State Electric Company, 1977 Congressional Dr. St. Louis, MO 63146 TEl: 866-354-0063 Website: http://www.furnas-controls.com/
Note: It's not clear that the company continues to supply pump pressure control switches - Ed. Oct. 2015 - Orange #PS6 pressure control switches [citation needed]
- Pedrollo FLUX ELECTRONIC FLOW CONTROL SWITCH [PDF]
- Reznor Replacement Pressure Switch Kits: www.RezSpec.com; (800) 695-1901, this pressure switch repair kit is used on Reznor® Model Series ADF, ADFH, RDF, DV, DFAH, DFAV,
SC, SCA, SCB, SCE, SSCBL, *RP, *RPV, *RPB, *RPBL, and PGBL - Shurflo tank pressure switch, Shurflo # 94-090-01 'TSO Tank Pressure Switch 1/4' with wiring harness (about $20. U.S.)
- SQUARE D PUMPTROL 9013 INATALLATION & WIRING PAMPHLET [PDF] enclosed with the switch. Schneider Electric USA 1415 South Roselle Road Palatine, IL 60067 Customer Care Center: 1-888-778-2733 Web: www.schneider-electric.us
- SQUARE D PUMPTROL 9013 TROUBLESHOOTING [PDF] guide from Schneider Electric
- SQUARE D 9013F & G PRESSURE SWITCH MAINTENANCE & TROUBLESHOOTING GUIDE [PDF]
- SQUARE D 9013 F & G PUMPTROL CATALOG & SPECIFICATIONS [PDF]
- SQUARE D CONTROL CATALOG [PDF]
- SQUARE D PRESSURE & VACUUM SWITCHES 9013FHG GHG SPECIFICATIONS [PDF] retrieved 2018/06/22 original source http://www.hfwinc.com/uploads/specs/Square_D_Pressure_Switches.pdf
- SQUARE D PUMPTROL 9013 PRESSURE SWITCH SPECIFICATIONS [PDF]
- SQUARE D PUMPTROL 9013 WIRING & ADJUSTMENT [PDF]
- SQUARE D Pumptrol 9013 PRESSURE CONTROL BROCHURE [PDF] retrieved 2018/02/14, original source: https://www.homedepot.com/catalog/pdfImages/c4/c45d9a6c-4498-438b-962f-9e546d196127.pdf
- Square-D Pumptrol: Pumptrol® Pressure Switch Adjustment, Square D, Schneider Electric Corporation, 8001 Knightdale Blvd., Knightdale< NC 27545 1-888-778-2733 - Square D Technical Library, web search 07/24/2010 original source: http://ecatalog.squared.com/techlib/docdetail.cfm?oid=09008926800a93be
- Square-D: 9013 Pumptrol® Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G, Catalog, SquareD, Schneider Electric Industries SAS, Schneider Electric Industries SAS, web search 02/23/2011, original source: http://ecatalog.squared.com/pubs/Machine Control/
Pressure-Float-Vacuum Switches/Pressure Switches-Water and Air/9013CT9701.pdf
Square D is a brand of Schneider Electric. - Square-D: Class 9013 Square D Commercial Pressure Switches: Water Pump Pressure Control Switch Class 9013, Type F, G, Manual, Square D Company, 8001 Highway 64 East, Knightdale, NC 27545-9023, USA, (919) 266-3671, www.squared.com, web search 02/24/2011, original source: stevenengineering.com/tech_support/PDFs/45COM.pdf. Quoting:
The Type FSG, FYG, FRG - PUMPTROL® Water Pump Pressure Switches are used to control Water Pump Pressure Switches are used to control
electrically driven water pumps and have the following features:- The Type FSG is the standard water pump switch, suitable for all types of pumps: jets, submersible,
reciprocating, etc. - The Type FYG is designed to meet higher horsepower and pressure requirements.
- The Type FRG is reverse acting: the contacts open on falling pressure.
All are diaphragm actuated.
The Type G - PUMPTROL® Commercial/Light Industrial Pressure Switch is used to control electrically driven water pumps and air compressors. It has higher electrical ratings for direct control of motors in pump and compressor applications. The Type G switch is diaphragm actuated and has contacts that open on rising pressure. - The Type FSG is the standard water pump switch, suitable for all types of pumps: jets, submersible,
- WATER PUMP PROTECTION SWITCH - automatically or manually-reset cut-offs that protect the pump in event of low water pressure or rapid pump cycling
- Square D 9012 pressure switches are not used on water pump systems. The Square-D 9012-series switches are control circuit rated devices used in pneumatic or hydraulic systems on a wide variety of machine and process applications to protect the equipment and control or monitor the system pressure.
- STA-RITE PENTAIR PUMP CONTROL SWITCH ADJUSTMENT [PDF], retrieved 2018/06/22, original source: http://www.sta-rite.com/resources/images/13433.pdf
- Sta-Rite / Pentair USA 293 Wright Street Delavan, WI 53115 Tel: 888-782-7483 Orders Fax: 800-426-9446
- Sta-Rite / Pentair Canada 490 Pinebush Road, Unit 4 Cambridge, Ontario, Canada, N1T 0A5 Phone:300-363-7867 Fax:888-606-5484
Question: well pump tank makes a noise after tank begins to fill
(June 28, 2011) elmer said:
Is a good article but i still with my question because i did not find the answer . My well pump tank make a noise after the tank begins to fill again?..The pressure control works fine.
Reply:
It might be normal to hear a noise at the pressure tank when the pump is running, as water is flowing into the tank. If you hear air gurgling then there may be a leak in your well line causing the pump to also send air into the tank.
See
Question: pump control relay clicks clicks clicks at end of cycle
(July 19, 2011) carter said:
i have a question,i have a new installed jet pump...6 months,when i flush my toilet my pump will run for maybe 20/30 seconds,
it runs fine,but when its right at the end,the pressure points will snap on and off right fast 3/4 times,i adjusted the screw and it worked good for a day now its doing the same thing,runs smooth until right the end,then click,click,click,
Reply:
Pump pressure control switch contact bouncing?
It sounds as if the contact switch points may be burned; take a look, or try replacing the switch.
I am guessing in that direction because at the end of a pump cycle even if the pressure sensor of the switch is not working properly I wouldn't expect pressure sense to drop so far as to fall below the cut-in right at the END of the pump cycle.
Question: pressure drops to zero and pump stops unless manually re-set
(Aug 30, 2011) Janice said:
I have a question. We have a pressure control switch lever (as shown above) that we need to re-gauge if we run two faucets (or demand too much water) at one time. The pressure will drop to zero and we need to engage it in order to get the water working again.
Any suggestions on what would be causing this? This also happens if we run the faucet in the tub or the washer. Thanks!
Reply:
Janice if your water pressure is dropping to zero, the problem sounds like more than just adjusting the pressure control switch. It sounds as if the well pump is not keeping up with the water flow rate demand in the building. Or your well itself cannot keep up.
Before trying to adjust the pressure control switch I'd check out the well flow rate itself.
Question: pressure drops below the pump cut-in set pressure before the pump comes on
(Sept 5, 2011) Jim said:
I've adjusted cut on and off pressures, etc. My problem is that when the pressure drops through the cut in point, the switch 'tries' to trip. The contacts close briefly, pump just starts to turn, then everything stops and pressure falls. I can start it with the manual switch and it will run fine .
Pressure tank is brand new, and adjusted to about two pounds below cut in pressure. Any ideas?
(Oct 18, 2011) Kerry said:
Pressure control switch isn’t turning on the pump - when using the manual cut in switch the pump isn’t turning on either, however, if you manually use a screwdriver and push the contacts down you can get the pump to engage.
Hold the contacts down and you can get the tank up to pressure, however as soon you run out of pressure you have to go down with your screwdrivers and get the pressure back up
Hmmmm whats going on?
Reply: check for a debris clogged pump pressure switch or sensor port or tubing
Jim,
I realize there could be another problem, such as with the pump itself, but I'd start by replacing the pressure switch.
Also replace or clean out the switch mounting tube so we're sure it's properly sensing water pressure.
Kerry:
it's possible that the pressure sensing port on the bottom of your pressure control switch is clogged and not properly sensing water pressure.
If the switch thinks that you are above the cut-off pressure it won't turn on the pump. Another possibility is that the switch contacts are burned.
Square D Pressure Switch 9013fsg Manual Pdf
I'd try replacing the switch and making sure the little tube on which it mounts is also unblocked by rust or debris.
Question: pump came on for just 10 seconds
(Oct 21, 2011) Andrew said:
I have a relatively new Gould. Today I noticed the pressure was not right then it finally had no pressure. While in the pump house I re-booted the power. The pump came on for about 10 seconds and then shut off again. Again, I said it is about 3 1/2 years old and all the contacts I looked at look like the day it was put in. What is the most likely problem ? Pressure control switch - capacitor etc... Thanks for your help
(Jan 12, 2012) warren said:
my presure switch is tapping on/off on/off when i turn my tap on. what could be the cause?
Reply:
Andrew check the actual pressure in your system, then run water. Watch to see the pressure at which the pump cuts on. Then turn off water and watch to see the pressure at which the pump cuts off.
If the pump cuts off very quickly I suspect the water tank is water-logged - it's lost its air charge.
Warren,
See WATER PUMP SHORT CYCLING
(Feb 13, 2012) Rob said:
@Warren - two things come to mind that can cause that (as I just had the same problem). A bad pressure tank can cause your pump to kick in and out repeatedly while running water. The other potential problem is the setting on the pressure switch itself.
If the in and out are too close it would cause this. If you haven't adjusted your pressure switch I would check the air pressure in your tank. If you press the valve down and get water, then you've most likely got a ruptured bladder in your tank.
Question: testing my pump switch I saw a spark, then everything went dead - how do I select a new pump switch
(Jan 11, 2012) Steve said:
Square D 9013FSG 2 pressure control switch. While testing with a VOM probe, I got a small spark and everything went from dead to working normally (I think...at least the water is back on).
If I eventually need to replace this switch, are there several varieties of the 9013FSG 2? How do I know what version to get? The tank is a red AMTROL H20W-TO WATERWORKER 9015-585 in a residential installation.
Reply:
Steve, just match the new switch to the original one by
brand and model or part number
equivalent brand and model chosen by the factory pre-set cut-im and cut out pressure
Question: new pressure switch not working
(Jan 12, 2012) Archie said:
just repaced breaker, wire, pressure regulator switch on home well pump and still nothing works. I checked the gauge tube for clogs and it was clear, when I open the contact points, there is no spark, but there is power going to them, what am I missing
Reply:
Archie, you need to run water until pressure in the pressure tank drops below the cut-in pressure set in the control.
...
Continue reading at WATER PUMP PRESSURE SWITCH INSTALL / REPLACE or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Water Pressure Control Articles
- WATER PRESSURE LOSS DIAGNOSIS & REPAIR - home
- WATER PUMP PRESSURE CONTROL SWITCH - home
- PUMP CONTROL STATUS INDICATORS - indicator lights on pressure controls & pump controls
- PUMP PRESSURE SWITCH REPAIR KIT to replace contact points or diaphragm in a pressure control switch.
- WATER PUMP SHORT CYCLING - home
- WATER PUMP REPAIR GUIDE - home
- WATER PUMP SHORT CYCLING - home
- WATER TANK: USES, TROUBLESHOOTING - home
- WELL PIPING REPAIRS - separate article
Suggested citation for this web page
WATER PUMP PRESSURE SWITCH MANUALS at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Square D Pressure Switch 9013fsg Manual Transmission
INDEX to RELATED ARTICLES: ARTICLE INDEX to WATER SUPPLY, PUMPS TANKS WELLS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
...
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Technical Reviewers & References
- Thanks to reader Bob Hartman-Berrier for discussing the diagnosis of a pressure switch that would not turn the pump on, traced to a switch tubing fit problem. June 2010.
- Square D Company, Schneider Electric - North American Operating Division, 1415 S. Roselle Road, Palatine, IL 60067, Tel: 847-397-2600, Fax: 847-925-7500
- Square D 9013 series pressure control switches provide these special water pressure control switch features: narrow pressure differential controls, higher horsepower pump control switches, manual on/off switches, automatic low water pressure cut-off, pulsation plugs, and other features.
- Narrow Differential Pressure SwitchesSchneider Electric provides narrow differential switches including 6-20PSIG differential switches. Choose from the 9013FSG42/49 or higherHP 9013FYG42/49. Also available is the 9013FRG with reverse action.The 9013FRG pressure switch is non-adjustable differential with 6-14PSIG cut-in and 1-11 PSIG cut-out ranges.
- Higher HP Pressure SwitchesNeed a larger HP motor for longer runs in deep wells? Then look tothe 9013FYG or 9013GHG pressure switches. These switches directlycontrol all types of pumps up to 5 HP and can be used in the controlcircuit of a magnetic starter for even larger pumps.
- Manual On/Off SwitchThe 9013 series of pressure switches offer an optional on/off switch.This allows you to manually turn on and off your pump system forextended periods of time.
- Automatic Low Pressure/Water Cut-offIf system pressure is lost for any reason, a low water condition forexample, the automatic lower pressure/water cutoff feature will openthe contacts, turning off the pump.
- Pulsation PlugPulsation plugs are available to control pressure due to increased startup pressure generated by high speed jet pump motors or by valvesprone to a surge in pressure.
Flexcon, SMART TANK INSTALLATION INSTRUCTIONS [PDF], Flexcon Industries, 300 Pond St., Randolph MA 02368, www.flexconind.com, Tel: 800-527-0030 - web search 07/24/2010, original source: http://www.flexconind.com/pdf/st_install.pdf - Grove Electric, Typical Shallow Well One Line Jet Pump Installation [PDF], Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, Vancouver WA 98665 www.grovelectric.com - web search -7/15/2010 original source: http://www.groverelectric.com/howto/38_Typical%20Jet%20Pump%20Installation.pdf
- Grove Electric, Typical Deep Well Two Line Jet Pump Installation [PDF], Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, Vancouver WA 98665 www.grovelectric.com - web search -7/15/2010 original source: http://www.groverelectric.com/howto/38_Typical%20Jet%20Pump%20Installation.pdf
- Penn State, Water Fact Sheet #3, USING LOW-YIELD WELLS [PDF], Penn State College of Agricultural Sciences, Cooperative Extension, School of Forest Resources, web search 07/24/2010, original source: http://pubs.cas.psu.edu/FreePubs/pdfs/XH0002.pdf
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
- Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
- ...
- Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. The firm provides professional HOME INSPECTION SERVICES and also extensive HOME INSPECTION EDUCATION and home inspection-related PUBLICATIONS. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides extensive home inspection education and report writing material.
The ILLUSTRATED HOME illustrates construction details and building components, a reference for owners & inspectors.
Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page 'Promo/Redemption' space.
TECHNICAL REFERENCE GUIDE to manufacturer's model and serial number information for heating and cooling equipment, useful for determining the age of heating boilers, furnaces, water heaters is provided by Carson Dunlop Weldon & Associates
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on any number of copies of the Technical Reference Guide purchased as a single order. Just enter INSPECTATRG in the order payment page 'Promo/Redemption' space. - The HOME REFERENCE BOOK - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume.
Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author.
Or choose the The HOME REFERENCE eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones.
Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page 'Promo/Redemption' space. - Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
COMMERCIAL BUILDING INSPECTION COURSES - protocol ASTM Standard E 2018-08 for Property Condition Assessments
HOME INSPECTION EDUCATION COURESES (Canada)
HOME INSPECTION EDUCATION COURSES (USA) including home study & live classes at eleven colleges & universities.
HOME INSPECTION EDUCATION: HOME STUDY COURSES - ASHI@Home Training 10-course program.
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author. - The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones
SQUARE D Series How to Install Your Pressure Switch Square D F Pressure Switch Wiring Diagram · Square D F Data Bulletin · Square D. Buy your GHG2J30 from an authorized SQUARE D BY SCHNEIDER ELECTRIC distributor. GHG2J30 - Pressure Switch, GHG, 1/4' NPSF, 40 psi.
Square D Pressure Switch 9013 Adjustment
square d air compressor pressure switch wiring diagram starter wiring Square D Pressure Switch Wiring Diagram Air Compressor. square d air compressor pressure switch wiring diagram starter wiring Square D Pressure Switch Wiring Diagram Air Compressor.
Video - How to install your Pumptrol pressure switch FSG . I'd like to receive news and commercial info from Schneider Electric and its affiliates via.Commercial Pressure Switches Electromechanical Square D Brand For power circuits, FSG, FTG, FYG, FRG, FHG, and G When setting the pressure switch, adjust the switching point on rising pressure first and then the switching point on falling pressure. Switching point on falling pressure.
Square D Commercial Pressure Switch FSG Series 20 to 65 PSIG The Type FSG - PUMPTROL® Water Pump Pressure Switches are used to control electrically driven water pumps. Operates regulation between 2 thresholds (with an adjustable differential). Jul 03, · square d pressure switch wiring diagram imageresizertool square d pressure switch wiring diagram furthermore waterway w further watch further product along with pressure switch nut adjust as well as volt switch.
wiring a square d™ power pressure switch tutorial for proper wiring of square d™ power pressure switches to learn. Minecraft Circle Diagram.
Standing Rigging Diagram. 3 Position Switch Wiring Diagram.
Ocean Ecosystem Food Chain Diagram. Plano Concave Lens Ray Diagram.
Chevrolet C Wiring Diagram. Fantastic Fan Wiring Diagram.
Simple Boat Wiring Diagram. Browning Buckmark Parts Diagram. Giant Octopus Diagram.
Square D Pressure Switch For Air Compressor
Dodge Durango Wiring Diagram. Square D Pumptrol FSG well tank pressure switches are the industry standard for household well installations.
Square D Pressure Switch Catalog
They are easy to install, have adjustable cut-in and cut-out settings and can control both submersible pumps and jet pumps. Features: Factory Set Cut-In Pressure: 40 psi Factory Set Cut-Out Pressure: 60 psi.Wiring Help On Pumptrol Pressure Switch - schematron.org Community Forumsschematron.org: Online Shopping for Electronics, Apparel, Computers, Books, DVDs & more
Comments are closed.